5/12 roof pitch over a 24 ft span

5/12 pitch over a 24 ft span
13ft rafter
22.6° · ridge sits 5 ft above the wall plate
22.6°12 ft run5 ft rise13 ft rafter5/1241.7% · 22.6°× 1.083footprint → roof areaSingle underlayment
Rafter length12 ft half-span × 1.08313ft
With a 12″ overhangwhat you actually cut14.08ft
Ridge height above the wall5ft
Pitch factor√(1 + (5/12)²) — multiply footprint by this for roof area1.083
Angleset the mitre saw to this22.6°
As a percentage5/12 is 41.7%, not 5%41.7%
Roof area per 100 ft² of footprint108ft²
Asphalt shinglesingle layer of underlayment is enoughStandard
Walkableproper footwear and a harnessYes, with care
Pitch
5 /12
Span
24 ft

Three ways of saying the same slope

5/12 means 5 inches of rise for every 12 inches of run. As an angle that is 22.6°. As a percentage it is 41.7%.

People quote one and mean another constantly. 5/12 is not 5%, and it is not 5° either.

What you actually cut

The rafter is the hypotenuse, so it is always longer than the half-span. Over a 24 ft span the half-run is 12 ft and the rafter is 13 ft — plus the overhang, giving 14.08 ft to cut.

The ridge sits 5 ft above the wall plate.

The number worth keeping

The pitch factor is 1.083. Multiply any footprint by it to get roof area: 100 ft² on the ground is 108 ft² of roof at this pitch.

That single number is the difference between ordering enough shingle and ordering the footprint.

Where the pitch decides the material

Below 2/12, asphalt shingles are not permitted at all — water moves too slowly and wind drives it back under the courses. That roof needs a low-slope membrane.

Between 2/12 and 4/12, shingles are allowed but the IRC requires two layers of underlayment (R905.2.7). It is the most commonly skipped requirement on shallow roofs and the one that surfaces as a leak two winters later.

At 4/12 and above, a single layer is enough.

And where it decides the day rate

Above 8/12 most people cannot stand on a roof. Roof jacks, planks or scaffolding change the cost of the job more than any material choice does.

Notes

  • **Three ways of saying pitch, and they are not the same number.** 5/12 means 5 inches of rise per 12 inches of run. As an angle that is 22.6°. As a percentage it is 41.7%. People routinely quote one and mean another, and on a roof that mistake is expensive.
  • The rafter is the hypotenuse, so it is always longer than the half-span: 12 ft of run becomes 13 ft of rafter, plus 1.08 ft for a 12″ overhang. Cut to 14.08 ft and trim on the roof rather than the other way round.
  • At 5/12 a single layer of underlayment satisfies the code, and water sheds fast enough that wind-driven rain is not the concern it is on shallower roofs.
  • The pitch factor 1.083 is the number to keep: multiply any footprint by it to get roof area. A 100 ft² footprint is 108 ft² of roof at this pitch.
  • 5/12 is walkable with proper footwear and a harness. Wet, mossy or frosted, none of that holds.

Nearby sizes